Difference between revisions of "6502 Instructions - Introduction"

From CDOT Wiki
Jump to: navigation, search
(Created page with "{{Chris Tyler Draft}} Category:6502 The 6502 processor has a compact instruction set, consisting of just 56 instructions: <code> ADC AND ASL BCC BCS BEQ BIT BMI BNE B...")
 
(Miscellaneous Instructions)
 
(28 intermediate revisions by the same user not shown)
Line 1: Line 1:
{{Chris Tyler Draft}}
+
[[Category:6502]][[Category:Assembly Language]]
[[Category:6502]]
 
 
The [[6502]] processor has a compact instruction set, consisting of just 56 instructions:
 
The [[6502]] processor has a compact instruction set, consisting of just 56 instructions:
  
<code>
+
ADC AND ASL BCC BCS BEQ BIT
ADC AND ASL BCC BCS BEQ BIT BMI BNE BPL BRK BVC BVS CLC
+
BMI BNE BPL BRK BVC BVS CLC
CLD CLI CLV CMP CPX CPY DEC DEX DEY EOR INC INX INY JMP
+
CLD CLI CLV CMP CPX CPY DEC
JSR LDA LDX LDY LSR NOP ORA PHA PHP PLA PLP ROL ROR RTI
+
DEX DEY EOR INC INX INY JMP
RTS SBC SEC SED SEI STA STX STY TAX TAY TSX TXA TXS TYA
+
JSR LDA LDX LDY LSR NOP ORA
</code>
+
PHA PHP PLA PLP ROL ROR RTI  
 +
RTS SBC SEC SED SEI STA STX
 +
STY TAX TAY TSX TXA TXS TYA
  
This page groups these instructions and explains their basic function.
+
This page groups these instructions into functional categories and explains their basic purpose.
 +
 
 +
{{Admon/tip|Addressing Modes and Registers are essential!|Take the time to understand the [[6502 Addressing Modes|6502 addressing modes]] and [[6502#Registers|registers]]. This is essential background infromation for understanding the 6502 instructions.}}
  
  
 
== Addressing Modes ==
 
== Addressing Modes ==
  
There are 13 [[6502 Addressing Modes]]. All of these instructions work with at least one addressing mode, and many work with several addressing modes. See the [[#Resources]] section for Opcode tables that define which instructions work with which addressing modes.
+
There are thirteen [[6502 Addressing Modes]]. All of these instructions work with at least one addressing mode, and many work with several addressing modes. See the [[#Resources|Resources]] section for Opcode tables that define which instructions work with which addressing modes.
 +
 
 +
== Registers ==
  
 +
Most of these instructions work with [[Register|registers]]. Refer to the [[6502#Registers|6502 page, Register section]] for details on the 6502's internal registers.
  
 
== Performance ==
 
== Performance ==
  
Each 6502 instruction takes a defined number of cycles to execute. In some cases,  
+
Each 6502 instruction takes a defined number of machine cycles to execute. In some cases,the number of cycles will vary depending on the circumstances of the instruction's execution - for example, the conditional branch instruction <code>BRE</code> (Branch if EQual) takes:
 +
* 2 cycles if the branch is not taken
 +
* 3 cycles if a branch is taken to an address in the same page
 +
* 4 cycles if a branch is taken to an address in another page
 +
 
 +
Remember that the Program Counter (PC register) contains a pointer to the next instruction to be executed. When the BEQ instruction has been loaded into the CPU, the PC points to the instruction following the BEQ. The branch works by adding a signed integer value (in the range of -128 to +127) to the Program Counter; the extra cycle required when the branch is taken is used to process the addition. If the high byte of the Program Counter changes (because the branch crosses in to another page), one additional cycle is required to adjust the high byte.
  
 +
You can find the execution time in the instruction charts found in the [[#Resources|Resources]] section below.
  
== Loading and Storing Data (to/from Memory) ==
+
To convert the number of cycles to time, multiply the cycles by the time between system [[Clock|clock]] pulses. Many 6502 systems operated at 1 MHz (1 million operations per second), and therefore 1 cycle corresponded to 1 millionth of a second, or 1 microsecond (uS). Therefore, an instruction that took 4 clock cycles would take 4 uS to execute.
  
=== Register-Memory Loads and Stores ===
+
== Instructions by Category ==
 +
 
 +
=== Loading and Storing Data (to/from Memory) ===
 +
 
 +
==== Register-Memory Loads and Stores ====
  
 
There are three instructions to load data from memory to a register:
 
There are three instructions to load data from memory to a register:
  
<code>
+
LDA ; load the accumulator
LDA ; load the accumulator
+
LDX ; load the X register  
LDX ; load the X register
+
LDY ; load the Y register
LDY ; load the Y register
 
</code>
 
  
 
And there are three matching instructions to store data from a register to a memory location:
 
And there are three matching instructions to store data from a register to a memory location:
  
<code>
+
STA ; store the accumulator  
STA ; store the accumulator
+
STX ; store the X register  
STX ; store the X register
+
STY ; store the Y register
STY ; store the Y register
 
</code>
 
  
=== Push/Pull on the Stack ===
+
==== Push/Pull on the Stack ====
  
There are also two instructions to push data onto the stack:
+
When a value is pushed to the stack, the selected register is written to memory location $0100+SP and the stack pointer register (SP) is decremented.
  
<code>
+
When a value is pulled from the stack, the stack pointer register (SP) is incremented and the selected register is loaded from memory location $0100+SP.
PHA ; push the accumulator
+
 
PHP ; push the processor status register
+
There are two instructions to push data onto the stack:
</code>
+
 
 +
PHA ; push the accumulator
 +
PHP ; push the processor status register (SR)
  
 
And two matching instructions to pull data from the stack:
 
And two matching instructions to pull data from the stack:
  
<code>
+
PLA ; pull the accumulator
PLA ; pull the accumulator
+
PLP ; pull the processor status register (SR)
PLP ; pull the processor status registerI've been swamped!
+
 
</code>
+
Note that some other operations, such as JSR, interrupts, RTI, and RTS, cause data to be pushed to or pulled from the stack.
 +
 
 +
==== Transferring Data between Registers ====
 +
 
 +
The X and Y registers can be transferred to/from the accumulator:
 +
 
 +
TAX ; transfer A to X
 +
TAY ; transfer A to Y
 +
TXA ; transfer X to A
 +
TYA ; transfer Y to A
 +
 
 +
You can also transfer the Stack Pointer (SP) to/from the X register:
 +
 
 +
TSX ; transfer SP to X
 +
TXS ; tranfer X to SP
 +
 
 +
It is not possible to directly transfer the Status Register (SR) to a general-purpose register, but you can you transfer it via the stack (e.g., by pushing SR to the stack with with <code>PHP</code> and then popping the stack to the accumulator with <code>PLA</code>).
 +
 
 +
=== Arithmetic and Bitwise Operations ===
 +
 
 +
{{Admon/tip|Watch the Carry Flag!|Failing to clear the carry flag before addition or to set the carry flag before subtraction is the cause of many bugs in 6502 programs. The carry flag also affects the rotate instructions. Be sure to set or clear this flag with the <code>SEC</code> or <code>CLC</code> instructions when needed!}}
 +
 
 +
'''For full details on all of the arithmetic and bitwise instructions, see the [[6502 Math]] page.'''
 +
 
 +
The 6502 has basic addition and subtraction instructions, which operate on the accumulator (A):
 +
 
 +
ADC ; add with carry
 +
SBC ; subtract with carry
 +
 
 +
There are also increment and decrement instructions for the X and Y registers and for memory:
 +
 
 +
DEC ; decrement memory
 +
DEX ; decrement X register
 +
DEY ; decrement Y register
 +
 +
INC ; increment memory
 +
INX ; increment X register
 +
INY ; increment Y register
 +
 
 +
The 6502 also has instructions for left and right bit-shifts and rotations (which can act as multiply-by-2 and divide-by-2):
 +
 
 +
ASL ; arithmetic shift left
 +
ROL ; rotate left
 +
 +
LSR ; logical shift right
 +
ROR ; rotate right
 +
 
 +
There are also instructions for bitwise operations such as exclusive-OR, OR, and AND. Exclusive-OR with #$FF is equivalent to a NOT operation, and these operations can be combined to produce other logical operations such as NOR and NAND.
 +
 
 +
AND ; bitwise AND (with accumulator)
 +
EOR ; bitwise exclusive-OR (with accumulator)
 +
ORA ; bitwise OR (with accumulator)
 +
 
 +
=== Test and Comparison Operations ===
 +
 
 +
The A, X, and Y registers can be directly compared with immediate or memory values:
 +
 
 +
CMP ; compare accumulator
 +
CPX ; compare X register
 +
CPY ; compare Y register
 +
 
 +
These operations are performed by subtraction. The appropriate condition flags are set, and the result of the subtraction is discarded. Conditional branch instructions can be used to alter program flow based on the results of the comparisons.
 +
 
 +
There is another test instruction available:
 +
 
 +
BIT ; bit test
 +
 
 +
This instruction places bit 7 of the operand into the N flag and bit 6 of the operand into the V flag. The operand is then ANDed with the accumulator, and the Z flag is set if the result is zero. The result of the AND is discarded. In this way, you can test the value of bit 7, bit 6, or any arbitrary bits (using the operand).
 +
 
 +
Note that in addition to these instructions, many other instructions (such as register loads) affect condition flags.
 +
 
 +
=== Program Flow ===
 +
 
 +
==== Unconditional Jump ====
 +
 
 +
An unconditional jump is like a "Goto" -- it sets the address of the next instruction to be executed (by modifying the Program Counter (PC)):
 +
 
 +
JMP ; jump to address
 +
 
 +
==== Jump to SubRoutine ====
 +
 
 +
A jump to a subroutine is also unconditional, but the current value of the Program Counter (PC) is placed on the stack so that when the subroutine (aka procedure, function, or method) is finished, execution can resume at the instruction after the jump to subroutine:
 +
 
 +
JSR ; jump to subroutine (pushes PC on stack, loads operand into PC)
 +
RTS ; return from subroutine (pops PC from stack)
 +
 
 +
==== Conditional Branch ====
 +
 
 +
A conditional branch is like a jump, except that it is only performed if a certain condition is met:
 +
 
 +
BCC ; branch on carry clear (C flag is clear)
 +
BCS ; branch on carry set (C flag is set)
 +
BEQ ; branch if equal (Z flag is set)
 +
BMI ; branch if minus (N flag is set)
 +
BNE ; branch if not equal (Z flag is clear)
 +
BPL ; branch if plus (N flag is clear)
 +
BVC ; branch if overflow clear (V flag is clear)
 +
BVS ; branch if overflow set (V flag is set)
 +
 
 +
Note that the operand for conditional branch instructions is a relative offset - a signed 8-bit value (in the range -128 to +127) that is added to the current PC. When writing assembler (or viewing disassembled code), the operand is ''written'' as an absolute address or label, but the actual [[Machine Language|machine language]] code uses the relative addressing mode. For this reason, a branch that is too far will not assemble and will produce an error message.
 +
 
 +
=== Manipulating Flags ===
 +
 
 +
The 6502 provides instructions for setting and clearing various condition flags:
 +
 
 +
CLC ; clear carry flag (C) - required before using ADC (for single-byte and lowest-byte)
 +
CLD ; clear decimal flag (D) - switches into binary math mode
 +
CLI ; clear interrupt disable (I) - enables processor interrupts
 +
CLV ; clear overflow flag (V)
 +
 +
SEC ; set carry flag (C) - required before using SBC (for single-byte and lowest-byte)
 +
SED ; set decimal flag (D) - switches into decimal math mode
 +
SEI ; set interrupt disable - turns off processor interrupts
 +
 
 +
Note that there is no instruction to set the overflow (V) flag.
 +
 
 +
=== Miscellaneous Instructions ===
  
When a value is pushed to the stack, the stack pointer is decremented and the selected register is written to $0100+SP.
+
BRK ; "BREAK" - turn control over to the debugger
  
When a value is pulled from the stack, the stack pointer is incremented and the selected register is loaded from $0100+SP.
+
This instruction initiates a special version of the Non-Maskable Interrupt - "Non-maskable" meaning that the interrupt flag (I) cannot disable this signal.
  
Note that some other operations, such as JSR, interrupts, and RTS, cause data to be pushed to or pulled from the stack.
+
RTI ; return from interrupt
  
== Bitwise Operations ==
+
<code>RTI</code> is very similar to <code>RTS</code> (ReTurn from Subroutine), but is used to return from interrupts.
  
=== Arithmetic ===
+
NOP ; no operation
  
<code>
+
The <code>NOP</code> instruction does nothing. It can be used to pad code for alignment purposes, or unwanted code can be overwritten in situ with this opcode to disable it.
ADC ; add with carry
 
</code>
 
  
The accumulator + memory location + carry flag is stored to the accumulator (<code>A = A + M + C</code>).
+
== Resources ==
  
The carry flag can be used to carry overflow information from the lowest byte to the highest byte of a multi-byte addition. Clear the carry flag and then add the lowest bytes, then leave the carry flag untouched and add the second-lowest bytes. Continue to the highest byte in the multi-byte sequence.
+
These resources provide detailed summaries of the 6502 instructions, including the number of cycles required to execute the instructions, flags affected by each instruction, and the addressing modes available:
 +
* [http://www.6502.org/tutorials/6502opcodes.html 6502 Opcodes with Register Definitions]
 +
* [https://www.masswerk.at/6502/6502_instruction_set.html 6502 Opcodes with Detailed Operation Information]

Latest revision as of 00:59, 11 September 2023

The 6502 processor has a compact instruction set, consisting of just 56 instructions:

ADC	AND	ASL	BCC	BCS	BEQ	BIT	
BMI	BNE	BPL	BRK	BVC	BVS	CLC  
CLD	CLI	CLV	CMP	CPX	CPY	DEC
DEX	DEY	EOR	INC	INX	INY	JMP
JSR	LDA	LDX	LDY	LSR	NOP	ORA
PHA	PHP	PLA	PLP	ROL	ROR	RTI 
RTS	SBC	SEC	SED	SEI	STA	STX
STY	TAX	TAY	TSX	TXA	TXS	TYA

This page groups these instructions into functional categories and explains their basic purpose.

Idea.png
Addressing Modes and Registers are essential!
Take the time to understand the 6502 addressing modes and registers. This is essential background infromation for understanding the 6502 instructions.


Addressing Modes

There are thirteen 6502 Addressing Modes. All of these instructions work with at least one addressing mode, and many work with several addressing modes. See the Resources section for Opcode tables that define which instructions work with which addressing modes.

Registers

Most of these instructions work with registers. Refer to the 6502 page, Register section for details on the 6502's internal registers.

Performance

Each 6502 instruction takes a defined number of machine cycles to execute. In some cases,the number of cycles will vary depending on the circumstances of the instruction's execution - for example, the conditional branch instruction BRE (Branch if EQual) takes:

  • 2 cycles if the branch is not taken
  • 3 cycles if a branch is taken to an address in the same page
  • 4 cycles if a branch is taken to an address in another page

Remember that the Program Counter (PC register) contains a pointer to the next instruction to be executed. When the BEQ instruction has been loaded into the CPU, the PC points to the instruction following the BEQ. The branch works by adding a signed integer value (in the range of -128 to +127) to the Program Counter; the extra cycle required when the branch is taken is used to process the addition. If the high byte of the Program Counter changes (because the branch crosses in to another page), one additional cycle is required to adjust the high byte.

You can find the execution time in the instruction charts found in the Resources section below.

To convert the number of cycles to time, multiply the cycles by the time between system clock pulses. Many 6502 systems operated at 1 MHz (1 million operations per second), and therefore 1 cycle corresponded to 1 millionth of a second, or 1 microsecond (uS). Therefore, an instruction that took 4 clock cycles would take 4 uS to execute.

Instructions by Category

Loading and Storing Data (to/from Memory)

Register-Memory Loads and Stores

There are three instructions to load data from memory to a register:

LDA ; load the accumulator
LDX ; load the X register 
LDY ; load the Y register

And there are three matching instructions to store data from a register to a memory location:

STA ; store the accumulator 
STX ; store the X register 
STY ; store the Y register

Push/Pull on the Stack

When a value is pushed to the stack, the selected register is written to memory location $0100+SP and the stack pointer register (SP) is decremented.

When a value is pulled from the stack, the stack pointer register (SP) is incremented and the selected register is loaded from memory location $0100+SP.

There are two instructions to push data onto the stack:

PHA ; push the accumulator
PHP ; push the processor status register (SR)

And two matching instructions to pull data from the stack:

PLA ; pull the accumulator
PLP ; pull the processor status register (SR)

Note that some other operations, such as JSR, interrupts, RTI, and RTS, cause data to be pushed to or pulled from the stack.

Transferring Data between Registers

The X and Y registers can be transferred to/from the accumulator:

TAX ; transfer A to X
TAY ; transfer A to Y
TXA ; transfer X to A
TYA ; transfer Y to A

You can also transfer the Stack Pointer (SP) to/from the X register:

TSX ; transfer SP to X
TXS ; tranfer X to SP

It is not possible to directly transfer the Status Register (SR) to a general-purpose register, but you can you transfer it via the stack (e.g., by pushing SR to the stack with with PHP and then popping the stack to the accumulator with PLA).

Arithmetic and Bitwise Operations

Idea.png
Watch the Carry Flag!
Failing to clear the carry flag before addition or to set the carry flag before subtraction is the cause of many bugs in 6502 programs. The carry flag also affects the rotate instructions. Be sure to set or clear this flag with the SEC or CLC instructions when needed!

For full details on all of the arithmetic and bitwise instructions, see the 6502 Math page.

The 6502 has basic addition and subtraction instructions, which operate on the accumulator (A):

ADC ; add with carry
SBC ; subtract with carry

There are also increment and decrement instructions for the X and Y registers and for memory:

DEC ; decrement memory
DEX ; decrement X register
DEY ; decrement Y register

INC ; increment memory
INX ; increment X register
INY ; increment Y register

The 6502 also has instructions for left and right bit-shifts and rotations (which can act as multiply-by-2 and divide-by-2):

ASL ; arithmetic shift left
ROL ; rotate left

LSR ; logical shift right
ROR ; rotate right

There are also instructions for bitwise operations such as exclusive-OR, OR, and AND. Exclusive-OR with #$FF is equivalent to a NOT operation, and these operations can be combined to produce other logical operations such as NOR and NAND.

AND ; bitwise AND (with accumulator)
EOR ; bitwise exclusive-OR (with accumulator)
ORA ; bitwise OR (with accumulator)

Test and Comparison Operations

The A, X, and Y registers can be directly compared with immediate or memory values:

CMP ; compare accumulator
CPX ; compare X register
CPY ; compare Y register

These operations are performed by subtraction. The appropriate condition flags are set, and the result of the subtraction is discarded. Conditional branch instructions can be used to alter program flow based on the results of the comparisons.

There is another test instruction available:

BIT ; bit test

This instruction places bit 7 of the operand into the N flag and bit 6 of the operand into the V flag. The operand is then ANDed with the accumulator, and the Z flag is set if the result is zero. The result of the AND is discarded. In this way, you can test the value of bit 7, bit 6, or any arbitrary bits (using the operand).

Note that in addition to these instructions, many other instructions (such as register loads) affect condition flags.

Program Flow

Unconditional Jump

An unconditional jump is like a "Goto" -- it sets the address of the next instruction to be executed (by modifying the Program Counter (PC)):

JMP ; jump to address

Jump to SubRoutine

A jump to a subroutine is also unconditional, but the current value of the Program Counter (PC) is placed on the stack so that when the subroutine (aka procedure, function, or method) is finished, execution can resume at the instruction after the jump to subroutine:

JSR ; jump to subroutine (pushes PC on stack, loads operand into PC)
RTS ; return from subroutine (pops PC from stack)

Conditional Branch

A conditional branch is like a jump, except that it is only performed if a certain condition is met:

BCC ; branch on carry clear (C flag is clear)
BCS ; branch on carry set (C flag is set)
BEQ ; branch if equal (Z flag is set)
BMI ; branch if minus (N flag is set)
BNE ; branch if not equal (Z flag is clear)
BPL ; branch if plus (N flag is clear)
BVC ; branch if overflow clear (V flag is clear)
BVS ; branch if overflow set (V flag is set)

Note that the operand for conditional branch instructions is a relative offset - a signed 8-bit value (in the range -128 to +127) that is added to the current PC. When writing assembler (or viewing disassembled code), the operand is written as an absolute address or label, but the actual machine language code uses the relative addressing mode. For this reason, a branch that is too far will not assemble and will produce an error message.

Manipulating Flags

The 6502 provides instructions for setting and clearing various condition flags:

CLC ; clear carry flag (C) - required before using ADC (for single-byte and lowest-byte)
CLD ; clear decimal flag (D) - switches into binary math mode
CLI ; clear interrupt disable (I) - enables processor interrupts
CLV ; clear overflow flag (V)

SEC ; set carry flag (C) - required before using SBC (for single-byte and lowest-byte)
SED ; set decimal flag (D) - switches into decimal math mode
SEI ; set interrupt disable - turns off processor interrupts

Note that there is no instruction to set the overflow (V) flag.

Miscellaneous Instructions

BRK ; "BREAK" - turn control over to the debugger

This instruction initiates a special version of the Non-Maskable Interrupt - "Non-maskable" meaning that the interrupt flag (I) cannot disable this signal.

RTI ; return from interrupt

RTI is very similar to RTS (ReTurn from Subroutine), but is used to return from interrupts.

NOP ; no operation

The NOP instruction does nothing. It can be used to pad code for alignment purposes, or unwanted code can be overwritten in situ with this opcode to disable it.

Resources

These resources provide detailed summaries of the 6502 instructions, including the number of cycles required to execute the instructions, flags affected by each instruction, and the addressing modes available: